Furman - CN-3600S E
Artnr: IDS0034478
Tarneaeg: Kaup on ajutiselt otsas. Kontakteeruge meiega tarneaja prognoosiks. »
Teave:
AC Voltage Input Range
180-270VAC, 50/60Hz
Maximum AC Current Rating
16 amps (Thermal breaker)
AC Cord
1.5mm2x3, 2.5m Long, black, IEC C19 Female to Schuko CEE 7/7 Male Plug
AC Receptacles
Rear Panel Outlets: 1 IEC C13 pair (Unswitched), 3 IEC C13 pairs (Sequenced, each pair is controlled by separate relay)
Front Panel: 1 IEC C13 (Unswitched)
Surge/Under-Overvoltage Protection
AC Surge Protection: Series Multi-Stage Protection SMP
Spike Protection Mode: Line to neutral, zero ground leakage
Spike Clamping Voltage: 375V peak @ 6,000 volts/3,000 amps
Response Time: 1 nanosecond
Maximum Surge Current: 6,500 Amps
AC Undervoltage Protection: EVS, 175VAC+/-3VAC
AC Overvoltage Protection: EVS, 275VAC+/-5VAC
AC Overvoltage Reset Modes: Manual and Auto-reset (configurable)
AC Filtering
LiFT
Noise Attenuation: Linear, 10dB @10KHz, 40dB@100KHz, 50dB@500KHz
Operating Temperature Range
5C (40F) to 40C (105F) degrees
Humidity Range
<90% rH (Relative Humidity)
User Interface
Keyswitch: Front panel, 3-position keyswitch (On, Off, Remote)
Keys: Included, 1 pair
Pushbutton Switch: Front panel, hidden by security cover
Circuit Breaker: Front panel, pushbutton, 20A Thermal Breaker
Front panel diagnostic indicators: Primary link, Secondary link, Ethernet, Remote off, Delay 1, Delay 2, Delay 3, Power, Protection OK, Extreme Voltage
Front Panel DIP Switches: Front panel. Hidden by security cover, 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off BND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual
Potentiometer: Front panel, hidden by security cover, fine tune delay adjust
Control/Status/Triggering (Rear Panel):
Remote Terminal: +5-30VDC In, 12VDC (12mA) Out
SmartSequencing: Phoenix 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000’ nominal)
Remote Terminal: Phoenix 4-Pin Connector With Screw Terminals; +12V, STAT, REM, GND (Class 2 Wiring)
Force Off/Delay 3 Terminal: Phoenix 5-Pin Connector With Screw Terminals, FORCE OFF, DELAY 3 (Class 2 Wiring)
RS-232 Compatible: Yes, DB-9 Connector
IP Addressability: Optional, via BB-RS232 Ethernet/RS-232 Adaptor (sold separately) for IP control via Telnet, HTTP, BlueBOLT®
Voltmeter: Available with RS-232/Ethernet option, ± 2VAC accuracy
Ammeter: Available with RS-232/Ethernet option, ±1A accuracy
Power Consumption (No Load):
10 Watts
Safety Agency:
NRTL-C, RoHS Compliant